AC
Motors
1/8 to 3 HP

Designed for all general purpose, hazardous industrial applications


| Standard Features | Specifications | Typical Locations | Explosion-Proof Capabilities |


Reliance® Electric S-2000 XP motors are designed to operate in harsh environments that contain gas, vapor, dust, fibers, flyings, or other materials that may have explosive properties. These motors are constructed to withstand an internal explosion, to prevent ignition of the environment surrounding the motor as a result of an internal explosion, and to operate with external surface temperatures that will not ignite the surrounding environment. With a Reliance S-2000 XP motor you have Reliance Electric’s many years of explosion-proof motor experience behind you. You are assured of a long lasting, reliable motor for your application.


Standard Features

  • Frame - Full seam weld. Optimum thickness for better heat dissipation. Ends turned for excellent fit to end shields. Frames primed with alkyd primer for corrosion resistance.
  • End Shields - Die cast aluminum with metal bearing bore inserts to provide extra strength and security.
  • Base - Heavy duty steel welded to frame.
  • Rotor - Cast aluminum with integrally cast fins for excellent cooling. Keyless design, heat shrunk to shaft, turned for proper air gap, and dynamically balanced - providing for a superior, more efficient electrical design.
  • Stator - Specially treated class "F" and "H" wire used with full slot liner material. Coil heads laced for improved mechanical strength. Stator tested before and after assembly providing optimum electrical integrity.
  • Insulation - Non-hygroscopic, baked-on insulation assures superior electrical strength.
  • Hardware - Zinc chromate plated, high strength, with hex heads. Plating provides exceptional corrosion protection.
  • Bearings - Double shielded. Oversized. Permanently lubricated with moisture resistant grease. Rugged - holds up in tough applications.
  • Conduit Box - Removable, oversized conduit box with grounding lug for ease of installation and safety.
  • Shaft - High strength, carbon steel.
  • Connection Diagram - Permanently attached to motor.
  • Fan - Antistatic, bidirectional, corrosion resistant polypropylene. Provides superior cooling with reduced losses due to air movement. Keyed and clamped to prevent movement on the shaft.
  • Leads - Permanently marked providing fast identification.
  • Temperature Limiting Devices - Thermal protectors or thermostats included as standard. Assures rated skin temperature, providing maximum safety.
  • Certifications - U.L.Æ and CSA approved for hazardous locations.
  • Energy Saving Design - Provided by electrically matched rotor and stator which reduce primary and secondary losses.


Specifications

Horsepower 1/4 to 3
Speed* 3600, 1800, 1200, 900 RPM
Enclosure Totally Enclosed Fan-Cooled, Totally Enclosed Non-Ventilated
Frame 48, 56, 140T, and 180T
NEMA Design B
Power Supply Single-phase, 60 Hz, 115/208-230 or Three-phase, 60 Hz, 208-230/460 (A wide range of other frequencies and voltages are also available.)
Insulation Class F
Duty Continuous
Ambient 40ƒC
Service Factor 1.0 & 1.15

*Single-Phase 900 RPM not available.


Typical Locations

Class I - Explosion Proof

  • Petroleum refineries, and gasoline storage and dispensing areas.
  • Industrial firms that use flammable liquids in dip tanks for parts cleaning or other operations.
  • Petrochemical companies that manufacture chemicals for gas and oil.
  • Dry cleaning plants where vapors from cleaning fluids can be present.
  • Facilities that have spraying areas where products are coated with paint or plastic.
  • Aircraft hangars and fuel servicing areas.
  • Utility gas plants and operations involving storage and handling of liquified petroleum gas or natural gas.

Class II - Dust Ignition Proof

  • Grain elevators, flour and feed mills.
  • Plants that manufacture, use or store magnesium powders.
  • Plants that have chemical or metallurgical processes. . . producers of plastics and medicines.
  • Producers of starch or candies.
  • Spice-grinding plants, sugar plants and cocoa plants.
  • Coal preparation plants and other carbon-handling or processing areas.


Explosion-Proof Capabilities

  • Class I, Group D
  • Class I, Group D; Class II, Groups F & G
  • Class I, Group D; Class II Groups F & G with SXT features
  • Class I, Group D; Class II, Groups F & G Brake Motors
  • Class I, Group D; Class II, Groups F & G Synchronous Reluctance
  • Class I, Groups C & D; Class II, Groups F & G
  • Class I, Groups C & D; Class II, Groups F & G with SXT features and 60/50 Hz.
  • Class I, Groups C & D; Class II, Groups F & G with Inverter Duty features
  • Class I, Group D; Class II, Groups E, F & G
  • Gas pump motors
  • Other designs available


Ask for Assistance.

Before you buy another AC motor, check with your Reliance Electric sales engineer or distributor to determine why the Reliance Electric S-2000 XP motors are the proper choice. For further information about Reliance motor products, contact your local Reliance Electric sales office or authorized distributor or call:

1-800-245-4501

Reliance® is a trademark of Rockwell Automation.
Document b2758_1

Note: This material is not intended to provide operational instructions.
Appropriate Reliance Electric Industrial Company instruction manuals
and precautions should be studied prior to installation, operation, or
maintenance of equipment.

© 1998 Rockwell International, Inc.